Combustible gas alarm installation specifications and principles

Combustible gas alarm installation specifications and principles:
1. Effective coverage horizontal radius of combustible gas alarm: indoor should be 7.5m, outdoor should be 15m. A detector can be placed within the effective coverage area.
2. The alarm selection point should be within the range of 1 meter around the valve, pipe interface, air outlet or easy to leak, as close as possible, but does not affect the operation of other equipment.
3. The alarm should be installed in a place where the gas is easy to leak, easy to flow, and easy to stay. The installation position should be determined according to various conditions such as the density of the gas to be measured, the direction of the airflow at the installation site, and temperature.
4. When detecting methane, hydrogen and other flammable and/or toxic gases lighter than air, the installation height should be 0.5~2m higher than the release source, and the horizontal distance of the release source should be less than 5m.
5. Detecting combustible gas that is heavier than air. It is recommended that the installation height of the flammable gas alarm should be higher than the floor (or floor surface) by 0.3 to 0.6 m, and the horizontal distance from the release source should be less than 5 m. Installation too low can cause the detector to enter the water; too high is beyond the height at which the gas can accumulate.
6. When detecting a toxic gas (such as carbon monoxide) that is close to the molecular weight of the air and is easily mixed with air, the combustible gas alarm should be installed within a height of 1 m above and below the release source.
The flammable gas alarm installation specification elaborates on the installation principle of the alarm, etc., and must provide good guidance to the users who have installed the flammable gas alarm.

EO Sterilizer is a low temperature sterilization device. Based on the advantages of similar products at home and abroad, the product adopts latest materials, advanced computer technology, automatic control technology, welding technology and other technologies and techniques, it has the following features:

1. The whole sterilization process is controlled by microcomputer or computer with functions of automatic recording, printing and saving sterilizing technique parameters.

2. Adjustable hexahedral heating system is adopted, so the sterilizing temperature is even inside to ensure the consistency of sterilizing effects.

3. Specialized thermal insulation material to ensure the better insulation performance.

Technical Parameter

Size: 1m3-35m3

Power:6-55kw

Working pressure: -0.09 ~ 0.08 MPA

Working Humidity: 30%-60% RH

Environmental temperature::5℃~40℃

Relative humidity:≤80%

Water supply:water pressure:0.04~0.15MPa

Power supply:AC 220×(1±10%)V.50×(1±2%)HZ;

AC 380×(1±10%)V.50×(1±2%)HZ.

Steam supply:saturated steam, pressure≤0.15Mpa

eto sterilizer

FAQ:

1. Are you a manufacturer?

Yes, we are the professional manufacturer set up in 1992, located at a beautiful town of Zhejiang Province.

2. Can you provide the oversea service?

Yes, after the machines arrive at your factory, we will arrange engineers go to install the machine and train your operators.

3. Can we visit your factory?

Of course. We highly welcome clients come to visit our factory. It will be our great honor to meet you.

4. How can you guarantee the quality?

100% qualified products before the delivery. The clients can inspect the products at our factory.

1 year warranty ( failure caused by machine quality ) from the equipment arrive at the client`s factory. Lifetime maintenance and offer for the spare parts.

EO Sterilization Machine

ETO Sterilization Machine,ETO Sterilisation,EO Sterilization Machine,EO Sterilization

Yuhuan Zhengri Technology Co., Ltd. , http://www.syringemachine.com