China Domestic, Civil, Garden SS Solar Pump

Model NO.: Solar Pump
Power: Solar Energy
Start Up: Solar
Type: Solar
Application: Submersible Pump, Sewage Pump
Industry: Solar Pump
Media: Sewage Pumps
Performance: Multistage Pump
Theory: Centrifugal Pump
Motor Efficiency: Over 90%
Fluid T: 35°C
Sand Content: 0.25%
Max Immersion: 80m
Mini Diameter: 3"
Warranty: 2 Years
Original: China Pump
Lifetime: 5-8 Years
Use in: for Water Supply and Others
Other Details: Please check the following data
Trademark: Tailide
Transport Package: Export Wooden Case
Origin: Shenyang, China
HS Code: 8413810090

4PN SERIES SOLAR WATER PUMP

Features:
1. Each solar water pump is tested after 2-3 days, and the test can be completed before shipping from the factory.
2. Each motor uses an intelligent winding machine to ensure zero error during production.
3. We provide installation instructions, wiring guidance, and professional support for every customer.


Applications:
Groundwater supply to water treatment plants.
Irrigation in agriculture and horticulture.
Groundwater lowering.
Pressure boosting.
Industrial applications.
Water treatment systems.

Operating Conditions:
Maximum fluid temperature: up to 35°C
Maximum sand content: 0.25%
Maximum immersion depth: 80 meters
Minimum well diameter: 3 inches


Construction Characteristics of the Pump
Made with stainless steel, offering corrosion resistance, durability, and a sturdy coupling to the motor. The hexagonal pump shaft ensures effective impeller driving. A stainless steel non-return valve is installed in the discharge to protect the impellers and diffusers. The 4ST series pumps are compatible with 4SD motors.

Motor:
For details about the motor characteristics, please refer to the relevant motor section.

Warranty: 2 years
China Domestic, Civil, Garden SS Solar Pump

Common Questions Answered:
1. Is this solar water pump DC brushless?
Answer: Yes
2. What do the prices include?
Answer: Pump and controller
3. Can we match solar panels?

Answer: Yes, the pumps and solar panels need to be connected to the controller
4. Can the water pump connect directly to the solar panel?
Answer: No, the pump and solar panels need to be connected through the controller
5. Does the pump work at night?
Answer: It works only when there is daylight; batteries are needed for nighttime use

6. Can the battery outlet be matched?
Answer: Batteries are usually provided by the customer

China Domestic, Civil, Garden SS Solar Pump
China Domestic, Civil, Garden SS Solar Pump


Material:

Components Material
Pump external casing AISI304SS
Delivery casing Cast-Cu ASTM C85500
Suction Lantern Cast-Cu ASTM C85500
Diffuser Plastic.PC
Impeller Plastic.POM
Shaft AISI304SS
Shaft Coupling AISI304SS
Wear Ring AISI304SS
Motor external Casing Cast-Cu ASTM C85500
Top chock Cast-Iron ASTM C85500
Bottom support AISI304SS
Mechanical seal Special seal for deep well
Shaft AISI304SS-ASTM 5140
Bearing NSK
Seal lubricant oil Oil for food machinery and pharmaceutical use


Performance Data:

MODEL P2 DELIVERY N=2850 L/MIN
1-220-240V 3-380-415V KW HP Q 0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7
0 5 1.0 15 20 25 30 35 40 45
3SDM1.8/8 3SD1.8/8 0.18 0.25 H 35 34 34 33 32 29 26 22 17 11
3SDM1.8/11 3SD1.8/11 0.25 0.33 48 47 47 46 44 40 36 30 24 15
3SDM1.8/15 3SD1.8/15 0.37 0.5 65 64 64 63 60 55 49 41 33 21
3SDM1.8/21 3SD1.8/21 0.55 0.75 91 90 90 88 84 77 68 58 46 29

Bi-directional Ball Screws

Hojama High-precision bi-directional ball screws

​

Determination of Ball Screw Preload​

How is the preload for a ball screw determined? Applying preload to the nut within a ball screw assembly enhances the axial rigidity and positioning accuracy of the ball screw pair. Thus, when considering only the rigidity and positioning accuracy of the screw pair, a larger preload is more advantageous—it better eliminates axial clearance resulting from elastic deformation. Conversely, an overly small preload, even if it removes axial clearance, does not guarantee improved rigidity.​
 
The reason lies in the fact that the preload must be sufficient to eliminate the "low-stiffness zone" in the preloaded nut. Due to inherent errors (such as lead deviations) between the screw and nut components in the preloaded segment of a double-nut system, contact deformation can create uneven stiffness: some small sections may become tighter, yielding higher contact stiffness, while others may remain looser, leading to lower contact stiffness. This latter scenario is what is termed the "low-stiffness zone." To boost axial contact stiffness, the preload must be large enough to eliminate these low-stiffness zones, thereby genuinely achieving enhanced axial rigidity.​
 
That said, an excessively high preload is detrimental. It increases driving torque, reduces transmission efficiency, accelerates contact fatigue and wear between balls and raceways, and shortens the service life of the assembly.​
 

Inspection Work After Ball Screw Installation​

1. The rotation of the rotating system should be stable and flexible, with no jamming, looseness, or axial movement.​
2. Check whether the rotating system collides or interferes with fixed parts.​
3. Observe whether the supply or circulation of lubricating oil is normal, whether the gap of the sealing device is symmetrical, and whether all fasteners are loose.​
4. Check whether the end face of the inner ring of the linear bearing reliably abuts against the end face of the shaft shoulder and whether there is a gap between them. In addition, it is necessary to inspect the rotation accuracy, axial limit accuracy, working clearance of the linear bearing rotating system, and other necessary inspection items.​
When all the above inspection items are confirmed to be normal, the system can be put into use. However, if any abnormal signs are found, the use should be stopped immediately and the fault should be eliminated.​
 

Bi-directional Ball Screws,Precision Ball Screws,High-Quality Ball Screws

Suzhou Industrial Park Hojama Technology Co., Ltd , https://www.hojama-tech.com